Recording suspected controller faults in this way, by utilising one unique code, '4401', means the other 7 log locations are kept free for system faults such as low batteries, open circuit motor connections etc. You can also download, print, or export forms to your preferred cloud storage service. knowledge of PG Drives Technology electronic controllers. If this were not the case, the powerchair could move in an unexpected direction. PG Drives Technology products comprise of AC and DC motor controllers, systems for medical mobility powerchairs and wheelchairs, as well as other small electric vehicles. R-NET- TECHNICAL MANUAL SK77981/14 - PG Drives Technology . All rights reserved. The standard drive screen will be displayed - the controller is now unlocked. This indicates that the VR2 has been locked and cannot be driven. The most common cause of a '2F00' error is if the user has displaced the joystick away from centre, before they switch the controller on. If when investigating the historical log of a VSI, VR2, Egis or S-drive, you come across '4401' faults, start by checking the connections, motors & batteries. (On older products the code will simply be stored as it appeared at the time). This code can be read with one of our hand-held or PC programmers. A determination to provide the very best in innovative control solutions means customers are assured of excellent support during design and manufacture of their own products. In addition, a User Switch is required and connects to the Omni2 via the 1/8" (3.5mm) mono jack. The DTT will appear as a drive in the computer's drive list. Possible Joystick Trip If you have the necessary programmer and a 'generic' unit, it is possible to reduce the maximum current of a controller. However, if you have a 'customer specific' controller you must contact the relevant manufacturer for advice. As a general rule, a '4401' error will point to a possible controller fault but occasionally a '4401' error may be recorded as a result of a system problem. i45 and i70 i-Cover kit number is: D50434 The i140 and i180 Kit comprises of a molded metal cover (1), a rubber cable seal / gasket (2) and 2 screws. +44 (0)1425 271444 All trademarks acknowledged. 2.4.1 Trip diagnosis with the battery gauge The battery gauge Flash Codes are illustrated in Chapter 1 Section 8. This indicates the speed of the wheelchair is being limited for safety reasons. The following faults are presents in my system. CUSTOMER SUPPORT CENTER: Technical Manuals :: R-net Control System - 14 R-net CJSM2 - 03 Omni - 07 Bluetooth Module - 04 Input/Output Module - 01 R-net PC Programmer - 02 Ensure the wiring loom between the controller, the motor, the batteries & the status indicator, (usually a green LED on the tiller head), is connected securely & correctly. If the problems persist after you have made the checks described above please contact your service agent. PG Drives Technology ACT425S SIGMADRIVE Manuals Manuals and User Guides for PG Drives Technology ACT425S SIGMADRIVE. PG Drives Technology VR2 series Operation And Installation Manual During the stepping cycle, it will not be possible to drive the chair. PG Drives Technology :: Controllers for Wheelchairs, Scooters and If our controllers detect a fault with the electrical system of a mobility vehicle, they will bring the powerchair or scooter to a stop & output a 4-digit diagnostic code. Does the scooter power-up? i-Drive is designed to the requirements of EN60335-2-72 and all models are UL recognized. The user is presented with a display comprising of three red, four yellow and three green LEDs . Left Motor Wiring Trip Except as permitted by such terms, no part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or be any means electronic, mechanical, recording, or otherwise - without the prior written permission of PG Drives Technology. The S-Drive combines the proven reliability of PG Drives Technology design with all of the safety features expected from such a respected mobility electronics manufacturer The on-board diagnostic system can store and display status information not only for the S-Drive itself, but also for the other electrical components on the scooter. For example, it is possible to program a 40A Pilot down to a current limit of 25A for use on an indoor chair, however, at the same time it would be necessary to reprogram the maximum & minimum speeds for forward, reverse & turning. Find the right form for you and fill it out: Tulevaisuuden Suomessa tarvitaan enemmn No results. construed as a commitment by PG Drives Technology. Then, launch the app and log in or create an account to have access to all of the editing tools of the solution. Possible Control System Trip If a controller detects a fault in a powerchair system, it will stop the chair & then flash a series of segments on the bargraph. We have 1 PG Drives Technology ACT425S SIGMADRIVE manual available for free PDF download: Technical Manual PG Drives Technology ACT425S SIGMADRIVE Technical Manual (94 pages) AC TRACTION or 'B' level programming software, it is possible to break down the '4401' entries into their original constituent codes. How do I fill out pg drives technology fault codes on an Android device. VSI Flash Codes; VR2 Flash Codes; Pilot+ Flash Codes; S-Drive Flash Codes; Egis Flash Codes; Solo; X25/X30 Flash Codes; Trio+; I-Drive; Trip Codes. The right motor* has a short circuit to a battery. How do I complete pg drives technology on an iOS device? Check the connections and the Throttle. plus/minus Is it possible to view how long a scooter or powerchair has been driven for? Once you have determined that you have the correct 'D' type number, you must decide whether or not the controller has any programmable settings. Release the joystick. The right motor* has a bad connection. We will be looking into this with the utmost urgency, The requested file was not found on our document library. You may view your papers from anywhere with an internet connection. 'Customer specific' 'D' type numbers are only available to the manufacturer who first requested the hardware & software options on that particular product e.g. The padlock symbol will be displayed on the screen. PG Drives Technology Inc. Vehicle Display Gauge TruCharge Display a seating actuator has been raised above a certain height. The device comprises of a PG Drives Technology or Flightlink type inductive joystick connected to the Omni via the 9-way D-type connector. If you are in any doubt, please contact, For more information on individual fault codes please, Yes, you can get an upgrade & best of all it's free! PG Drives Technology ACT425S SIGMADRIVE Technical Manual (94 pages), Guidelines for Working on Electric Vehicles, Precautions for Working on Electric Vehicles, Tightening Torque for Battery and Motor Connections, Battery and Motor Wire Size and Type Selection, Battery and Motor Connection Crimps and Tooling, Connector 'A' - Vehicle Interface (16-Way), Pin 4 - Thermistor or Steering Potentiometer, Speed Limit 1 / Inching Speed - (Speed 1/Inchspd), Speed Limit 2 / Inching Time - (Speed 2/Inchtime), Anti Roll-Off (Hill Hold & Restraint) - (Off/Arol), Motor Temperature Sensor Type - (Mtemptyp), Motor to Vehicle Speed Ratio - (Spdratio), Direction Braking Voltage Minimum - (Bdvmin), Direction Braking Voltage Boost - (Bdvboost), Direction Braking Slip Minimum - (Bdsmin), Direction Braking Slip Boost - (Bdsboost), Neutral Braking Voltage Minimum - (Bnvmin), Neutral Braking Voltage Boost - (Bnvboost), Braking Motor Speed Base (Rated) - (Bspdbase), Ramp Delay for Inner Torque Loop - (Ramp Trq), Proportional Gain for Outer Speed Loop in Neutral Braking, Defining the Braking Motor Speed Base Point. PG Drives Dynamic Is the programmer displaying a 'trip' code, e.g. If you have access to a 'B' or 'O.E.M.' Select your file from the documents list and pick your export method. If all 5 LEDs are flashing & the battery gauge is steady, then the end user has simply pressed the 'mode' button. If you are unsure if you have the latest issue, please give us a call. As a company, we are under contract to sell this product, only to that manufacturer. However, to optimise the performance of the 'generic' controller on a powerchair or scooter, an engineering programmer will probably be required. Follow the steps below to benefit from the PDF editor's expertise: Register the account. To view the TruCharge diagnostic information specific to the Controller or Control System you are working with, please click above. GBK52040 Issue 9, June 2016 Curtiss-Wright / PG Drives Technology R-net - Permobil Curtiss-Wright / PG Drive Technology R-net - Quickie Quantum Q-Logic 3 (Curtis Instruments) Monitoring Can system functions be monitored? Deflect the joystick forwards until the JSM beeps. Fault codes can be read with a hand-held programmer such as a PP1a or by using the PC Programmer. You may save it as a PDF, email it, or upload it to the cloud. Draw or type your signature, upload a signature image, or capture it with your digital camera. PDF Mobility Diagnostic Guide - Pgdt This unique number identifies the exact hardware & software specification of the controller. Get your file. There are many other components that make up a scooter, all of which can potentially cause the vehicle to stop working. All trademarks acknowledged. PDF PCP Mobility Manual OEM - Electronic SK76668-08 Use of this site indicates acceptance of our Privacy Policy. Try it for yourself by creating an account! PG Drives Technology - Curtiss-Wright Service Center Curtiss-Wright | PG Drives Technology 6 | R-net CJSM2 Installation Manual | Table Of Contents SK81302-03 ABOUT THIS MANUAL The Technical Manual gives an introduction to the R-net CJSM2 Joystick Module, it should be read in conjunction with the R-net The reason why we do not list all of these additional codes is because there are no user serviceable parts in any of our products. If you have the latest manual, it's possible the controller maybe faulty. If you want to lock or unlock the file, click the lock or unlock button. If the 'live' code is classed as a possible controller fault, it will be recorded in the system log of a VSI, VR2, Egis or S-drive as a '4401'. Before rejecting the main unit however, is still worth checking that all the connections, wiring & batteries are in a good condition. Aggressive repair time targets have been set and in the majority of cases, these are bettered. Check the connections to the battery. Vehicle Display Gauge TruCharge Display. In addition to its use as a 'fuel gauge', the bargraph can also offer low-level diagnostic assistance. As always, if you are unsure about whether or not to return a controller, please contact us for further advice, we're here to help! Firstly, the product must be labelled with the same 'D' type number. Prices are therefore levied on an individual basis. -Can look at average daily drive time, how many hours turned on, and fault log. Email, fax, or share your pg drives technology fault form via URL. The battery needs charging or there is a bad connection to the battery. 1.16 Drive Slip Base -. pdfFiller makes working with documents easier than you could ever imagine. 3.2.2 USB A Check the battery connections. All rights reserved. Check all the connections and leads between the left motor and the Power Module. A free estimate prior to repair is available on request and all units are despatched with a full investigation report on the fault and its likely cause. It is not possible to program a lower powered controller to a higher current limit, due to hardware & software constraints. Before assuming the controller is at fault, you should conduct some basic checks first. The left motor* has a short circuit to a battery. PG Drives Technology Distributor - Discover our range | TVH It is important to realise that even though the controller is signalling a fault, it may not be the controller itself that is defective. If the end user is operating the controller correctly & '2F00' is still reported, the joystick itself may be faulty or damaged. PG Drives Technology, formerly known as Penny & Giles Drives Technology, began designing, manufacturing and marketing sophisticated motor speed controllers in 1976, and the company became established as the world's foremost supplier of such products for mobility vehicles. plus/minus My controller has failed. PG DRIVE TECHNOLOGY NEWVSI Technical Manual PG Drives Technology I-DRIVE Series Technical Manual PG DRIVES TECHNOLOGY DIAGNOSTIC TEST TOOL MANUAL DIAGNOSTIC TEST TOOL TECHNICAL MANUAL SK79393/1 SK79393/1 1 PG DRIVES TECHNOLOGY DIAGNOSTIC TEST TOOL MANUAL PG Drives Technology 2008 All rights reserved. 13 . High Battery Voltage Some of these products contain safety fences, which are only accessible using manufacturing level software. Solenoid Brake Trip Use of this site indicates acceptance of our Privacy Statement. Alternatively, if the scooter is fitted with an Egis or S-drive, you can use our PC based programmer. In addition, a User Switch is required and connects to the Omni via the 3.5mm/1/8" jack socket. . The powerchair's speed is then adjusted in the normal way by moving the joystick to the left or right. To determine if you have a 'generic' or 'customer specific' controller, please contact us here at. For more information on diagnostics, please. PG Drives Technology :: Online Diagnostics | Curtiss-Wright Service Center Home / Online Diagnostics / Flash Code List / VR2 Flash Codes Service Center VR2 Flash Codes Low Battery Voltage The battery needs charging or there is a bad connection to the battery. If the unit is a VSI or VR2, then the speed of the powerchair is being reduced by an inhibit signal. This method has been chosen to prevent problems arising from lost keys. Check all the connections and leads between the left motor and the battery. All rights reserved. The primary objective of this facility is to assist service personnel in finding the likely area of a detected trip within the whole vehicle electrical system. If the DTT powers up, but the drive does not appear in your list, you will need to allocate a new drive letter to the device on the PC. PG Drives Technology, formerly known as Penny & Giles Drives Technology, began designing, manufacturing and marketing sophisticated motor speed controllers in 1976, and the company became established as the world's foremost supplier of such products for mobility vehicles. D435 -- OK. In this case, the unit should be returned to. If it does not, then you can replace the existing controller with one of the same 'D' type. PDF S-DRIVE CONTROLLER DIAGNOSTIC BLEEP CODES - rousie.co.uk This causes the LEDs to flash, indicating to the end user that they are in 'speed adjust' mode. Add and change text, add new objects, move pages, add watermarks and page numbers, and more. PG Drives Technology SIGMADRIVE Series Technical Manual Joystick Displaced An excessive voltage has been applied to the Power Module. Except as permitted by such terms, no part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means electronic, mechanical, recording, or otherwise - without the prior written permission of PG Drives Technology. Further details of R-net screens and icons can be found in the product technical manual. Wheelchair Joystick Error codes with meanings / fixes We only charge for the parts used and the time taken to complete the repair. These items are available in kit format from PG Drives Technology. PG Drives makes the VSI, VR2, and the GC control systems for Pride and others. Pg drives technology ACT425S SIGMADRIVE Manuals | ManualsLib Type text, complete fillable fields, insert images, highlight or blackout data for discretion, add comments, and more. The joystick has been displaced whilst the control system is switched on. All trademarks acknowledged. Choose which you have. Make sure that all connections are secure. Please refer to your specific Operating System's help file for details of how this is achieved. Use of this site indicates acceptance of our Privacy Statement. A R-Net Control System w/Omni2. Scooter Controllers. plus/minus My PGDT controller has been damaged. Yes, provided you have an Egis, S-drive, Pilot+, VSI or VR2 control system fitted. Then click Done when you're done editing and go to the Documents tab to merge or split the file. PDF S-DRIVE CONTROLLER FAMILY TECHNICAL MANUAL SK76745/10 - Bigmotion This display gives an accurate reading of the amount of battery charge available to the controller. Tulevaisuuden Suomessa tarvitaan enemmn yrittjyytt ja yrittji - Vihdin, Form Software - Qualified Electronic Signature Online, Docx Software - Uniform Electronic Transactions Act Online, Docx Software - Certificate Of Completion Online. The exact reason will depend on the type of wheelchair, however, the most common cause is that the seat is in the elevated position. In addition to determining that you have the same 'D' type number, these controllers must also be checked to ensure they have the same programmable parameters. R-series . The adjustable range is 0Hz to 15.93Hz in 0.0625Hz steps. -MyLiNX App and in programming Can't monitor how often tilt is used, etc. The parking brakes have a bad connection. Each occurrence of the fault condition in the fault history contains information about when the fault condition occurred, is it a warning or a fault, is it a latched fault. PDF Complex Rehab Power Wheelchair Electronics Comparison Matrix The left motor* has a bad connection. Installation Manual . If you have 'generic' product and an engineering level programmer this will be relatively straightforward, especially if you are using a PC programmer. +44 (0) 1425 27144. Control System Locked You have been successfully registered in pdfFiller, This site uses cookies to enhance site navigation and personalize your experience. When a control system has detected a trip, a system trip is indicated.